A shipment is inspected in three stages: incoming material, in-process checks at the press and the molding machine, and final AQL sampling to ISO 2859-1 at inspection level II. The final sample is the last gate, not the only one, and a supplier that only does final inspection is telling you something.

Most buyers ask "what is your AQL" and stop there. The better question is which characteristics are in the inspection plan, because an AQL of 0.65 on a cosmetic check and an AQL of 0.65 on contact retention are not the same shipment.

The three stages

Stage What is checked Failure action
Incoming Resin grade and lot, brass strip temper, plating thickness cert Reject lot to supplier
In-process Pin retention force, insertion depth, flash, body dimensions Stop the machine, adjust, re-check
Final Dimensions, coplanarity, plating thickness, appearance, packaging count AQL accept or reject the lot

What is actually measured

Pin retention. A push-out force on a sample of pins per cavity. This catches the parts where the press was slightly off and the knurl did not bite. It is the check that predicts field failures better than anything cosmetic.

Coplanarity. Measured on a granite plate or with a laser, on SMT parts only. 0.10 mm for 2.54 mm pitch. This is the one that customers ask for a report on.

Plating thickness. X-ray fluorescence on the contact area and on the tail. Gold and nickel separately, because a part with 10 µin of gold and no nickel is not the part on the drawing.

Dimensions. Pin spacing, body height, tail length, overall length. First article plus a sample per lot.

What AQL means in one paragraph

For a lot of 10,000 pieces at inspection level II, general inspection level II gives a sample size of 200 and an accept number of 3 at AQL 0.65. If 3 or fewer parts fail, the lot passes. It is a statistical statement about the lot, not a guarantee about the part in your hand.

  • AQL 0.65 for critical characteristics: contact retention, coplanarity, plating thickness.
  • AQL 1.0 or 2.5 for cosmetic and marking.
  • AQL 0.65 on a 200-piece sample still allows three failures, so ask for the failure description too.

What the report should contain

Lot number, quantity, sample size, AQL level, the characteristics measured with nominal and tolerance, the actual readings, the accept or reject decision, and the inspector’s name with a date. A report that only says "PASS" is a receipt, not an inspection record.

We send the report with the shipment by default on custom parts, and on request for catalog parts. If a customer needs a first article to AS9102 or PPAP format, we do that as a separate document.

Do you inspect every lot or sample?

Every lot gets final sampling. Full inspection is only for first articles and for lots where a previous lot failed.

Can I set my own AQL?

Yes, and it is written on the purchase order. Tighter AQL means a larger sample and a higher inspection cost, which shows up in the price.

What happens if a lot fails?

It is sorted 100%, the failures are counted and reported, and the root cause is fixed at the machine. A lot that fails twice for the same characteristic stops the line until the cause is found.

Ask for a sample inspection report with your quote and see whether the numbers you care about are in it. Our process is described under quality; the plating numbers are explained in gold thickness and what it buys.